ImageMaster HR/HR TempControl/Universal - MTF measurement & Image quality testing
Product Overview
Software
Technical Data
Upgrades & Accessories
Knowledge Base
Product brochure .
ImageMaster HR 2 brochure Download
ImageMaster Universal brochure Download
ImageMaster HR IR brochure Download
ImageMaster HR brochure Download
ImageMaster HR brochure – Options and Upgrades Download
ImageMaster HR TempControl brochure Download
ImageMaster? HR TempControl – Testing image quality in temperature ranges from -40° C to 120° C
ImageMaster ? HR/HR TempControl/Universal .
Image quality testing for small and large lenses .
The devices ImageMaster ? HR and Universal provide an outstanding level of accuracy and flexibility when testing the MTF (modulation transfer function). The equipment is modular and upgradeable to allow for custom configuration as test requirements change. The instrument can be configured for testing optical systems with the object at infinity or object and image at finite conjugates. The accuracy of the measurement is traceable to international standards.
The ImageMaster ? HR offers versatile functionality for testing the image quality of small and medium-sized lenses, e.g. for smartphone, photo and film cameras. With the ImageMaster? HR TempControl test samples, which have to provide their optical functionality and performance at extreme temperatures, can be measured in a wide temperature range.
For medium and larger lenses, e.g. in camera lens manufacturing and the development of aerial lenses or lenses for space exploration, the horizontally mounted ImageMaster ? Universal offers the highest accuracy and maximum stability.
Highest accuracy .
The products ImageMaster ? HR and Universal fulfill highest customer requirements for image quality testing. ImageMaster ? HR is the preferred MTF test station for R&D labs worldwide. Measurements with increased accuracy and flexibility are the main focus.
Testing in a wide spectral range .
The wide model range of ImageMaster ? HR and Universal allows measurement of a large number of optical parameters over a wide spectral range. The ImageMaster ? HR?can be used to measure lenses in the spectral range NUV-VIS-NIR-MWIR-LWIR. The ImageMaster ? ?Universal is flexibly suitable for MTF Testing in the entire spectral range UV-VIS-NIR-SWIR-MWIR-LWIR.
Versatile range of applications .
The ImageMaster ? HR and Universal are available in numerous variants and also enable with different collimator options, e.g. mirror collimators, precise measurement of samples with large focal length ranges. For optical systems that are used under different temperature and weather conditions, measurements in a wide temperature range are possible with the ImageMaster ? HR TempControl.
Product Overview ImageMaster ? HR .
ImageMaster ? HR 2 .
Image quality testing with highest repeatability .
The ImageMaster ? HR 2 is our completely redesigned new version of the long-time successful ImageMaster ? HR – the worldwide standard for image quality testing of small and medium-sized lenses e. g. for smartphone-, photo- and film cameras.
High repeatability for all measurement parameters
New Software and ease of use
Extended range of measurable samples
More information .
Measurement values are highly stable and reliable, ensuring correlation worldwide
Flexible software support in combination with mechanical features contributes to better correlation testing
Optional implementation of encoders improves position accuracy, i.e. improvement of the accuracy and reproducibility of the focus position
Absolute FFL/BFL measurement
Many “off-the-shelf” solutions are available, for example Encircled Energy, Veiling Glare, PSF, and ESF
ImageMaster ? HR UltraPrecision .
Ultra-precise image quality testing .
For ultra-precise measurement of MTF and other optical parameters TRIOPTICS has developed the top model among the MTF test stations of our HR product series – the ImageMaster ? HR UP.
High-precision air bearing sample holder
Increased mechanical stability
Enhanced measurement reproducibility
More information .
Accuracy traceable to international standards
Fully or semi-automated, ultra-accurate, multifunctional MTF test station
R&D MTF test station for medium sized samples
MTF measurement at finite and infinite conjugates
Instrument available for NUV / VIS / NIR
Vertical set up for most convenient and easy lens positioning
Optimal design prevents vignetting
ImageMaster ? HR .
The preferred MTF test station worldwide .
The ImageMaster ? HR fulfils the high customer requirements for accuracy and flexibility in the measurement of image quality.
Fully or semi-automated, ultra-accurate, multi-functional MTF test station
Accuracy traceable to international standards
MTF measurement at finite and infinite conjugates
More information .
For small and medium sized samples
Available for NUV/VIS/NIR/LWIR spectrum
Vertical set up for most convenient and accurate lens positioning
Ultra-wide field angle of ± 110°
Optimal design prevents vignetting
ImageMaster ? HR MAX .
Testing with mirror collimators .
ImageMaster ? HR MAX has been developed for high-precision MTF testing in the VIS and IR range.
Available for NUV/VIS/NIR spectrum
Includes a high-quality mirror collimator, halogen light source and high resolution camera sensor
Accuracy traceable to international standards
More information .
Fully or semi-automated, ultra-accurate, multi-functional MTF test station
For medium sized samples
MTF measurement at finite and infinite conjugates
Vertical set up for most convenient and easy lens positioning
Ultra-wide field angle of ± 70°
Optimal design prevents vignetting
ImageMaster ? HR MAX IR .
High End MTF testing in the IR range .
The ImageMaster ? HR MAX IR is designed for the measurement of MTF and other optical parameters of today’s high-end IR optics in R&D and production.
Available for NUV/VIS/NIR/MWIR/LWIR spectrum (SWIR on request)
Includes a high-quality mirror collimator, broadband IR light source and IR focal plane array image sensor
Accuracy traceable to international standards
More information .
For small and medium sized samples
MTF measurement at finite and infinite conjugates
Time-saving area sensor method for LWIR and MWIR
Vertical set up for most convenient and easy lens positioning
Ultra-wide field angle of ± 70°
Optimal design prevents vignetting
ImageMaster ? HR TempControl .
Testing Image Quality in Temp. Ranges from -40°C to 120°C .
Many optical systems such as lenses and camera modules are used in a wide temperature range and must consistently maintain their full functionality and performance across varying temperatures. Athermal designs should minimize the thermal influences on opto-mechanical parameters.
Functionality testing of athermal optical designs
Temperature range: Standard: -10°C to 120°C, Upgrade: -40°C?to 120°C
Determination of the optical performance for a set of parameters
More information .
Specially developed temperature stable design
Test samples are isolated from the environment via a vacuum
Measurements in both the VIS spectrum and NIR range and easy conversion
Measurements in MWIR- and LWIR range
Stable mechanical design made of granite
Technical Data ImageMaster? HR TempControl
× Technical Data ImageMaster HR TempControl .
Parameter ImageMaster ? HR TempControl
Temperature Range .
Standard: -10°C … 100°C Upgrade: -40°C … 120°C .
Max. off-axis angle .
±70° .
Max. image height .
±25 mm .
Min. EFL (Effective Focal Length) of the sample .
2.5 mm .
Azimuth range .
Non rotatable .
Wavelength .
VIS: 450 … 750 nm MWIR: 3 … 5 ?m .
Close
Download Technical Data ImageMaster? HR TempControl
Product Overview ImageMaster ? Universal .
ImageMaster ? Universal .
Horizontal MTF measurement in a wide spectral range .
Innovative design, high quality and long-life components are combined in the ImageMaster ? Universal with user-friendly software. Its horizontal construction facilitates testing of large lenses.
Accurate measurement of virtually any existing lens system: infinite, finite, afocal
For high performance photographic imaging lenses up to high resolution telescopes
Spectral range of the MTF measurement from UV to visible spectrum to IR (NIR/SWIR/MWIR/LWIR)
More information .
On-axis and off-axis-measurement of the MTF
Modular and upgradable design
Module exchange within a few minutes (e.g. changing from VIS to IR)
MTF values traceable to international standards
Cover for collimators protects from ambient light and air turbulences
Technical Data ImageMaster? Universal
× Technical Data ImageMaster Universal .
Parameter ImageMaster ? Universal
Optical set up .
Finite, infinite or afocal .
Max. off-axis angle .
±180 .
Spectral range .
UV: 250 nm … 450 nm VIS: 450 nm … 700 nm NIR: 700 nm … 1.000 nm SWIR: 1.000 nm … 2500 nm MWIR: 3 ?m … 5 ?m LWIR: 7 ?m … 13 ?m .
Azimuth range .
360° .
Max. image height .
±50 mm .
Spatial frequency (in specification) Max. spatial frequency .
UV: 100 lp/mm VIS / NIR: 500 lp/mm SWIR: 120 lp/mm MWIR: 80 lp/mm LWIR: 60 lp/mm .
Accuracy (MTF on-axis and off-axis) .
±0.02 MTF on axis ±0.03 MTF off axis .
Repeatability (MTF on-axis and off-axis) .
±0.01 MTF .
EFL (Effective Focal Length) Accuracy .
±0.2 % .
Distortion Accuracy (without / with encoder) Repeatability (without / with encoder) .
±0.7 % / ±0.25 % ±0.3 % / ±0.1 % .
Lateral chromatic aberration Accuracy Repeatability .
±0.5 ?m ±0.3 ?m .
Longitudinal chromatic aberration Accuracy Repeatability .
±1 ?m 0.2 ?m .
CRA Accuracy Repeatability .
±1° ±0.4° .
FFL (relative) Accuracy Repeatability .
±2 ?m ±1 ?m .
Astigmatism Accuracy Repeatability .
±4 ?m ±1 ?m .
Field curvature Accuracy Repeatability .
±2 ?m ±1 ?m .
Remark: Vacuum qualified sample is required .
Close
Download Technical Data ImageMaster? Universal
ImageMaster ? Universal 3D
Full field MTF measurement system for infinite and finite object distances .
The ImageMaster ? Universal 3D enables the full field measurement without rotating the sample under test. The sample remains in a fixed horizontal position while the automated target generator and the image analyzer scan the complete target respectively image plane.
Full field measurement for infinite and finite measurement situations
Measurement of the modulation transfer function (MTF) off-axis and on axis
MTF values based on international standards
More information .
Fully automated, ultra-accurate, multi-functional MTF- Test Station
Optimal design prevents reduction of the image brightness
Motorized finite conjugates stage for long conjugate distances
High quality image analyzer
Collimator rotates around two axes to cover an object angle of ±60° over the full field azimuth
The reticle including illumination unit cover a rectangular object field of ±1100mm (horizontal) and ±800mm (vertical)
Request ImageMaster? HR / HR TempControl / Universal
× .
Your product request for ImageMaster ? ? R&D .
Which product are you interested in?
ImageMaster?HR UltraPrecision ImageMaster? HR ImageMaster? HR MAX ImageMaster? HR MAX IR ImageMaster? Universal ImageMaster? Universal 3D ImageMaster? HR TempControl Measurement service (ImageMaster? HR TempControl)
Title Mr. Mrs.
Optional
Your message
Mandatory fields
I hereby subscribe to receive the TRIOPTICS email newsletter that contains regular information about new products and events. My personal data will be used exclusively in accordance with the TRIOPTICS privacy policy and I can revoke my consent to this at any time with future effect, e.g. via the unsubscribe link in the newsletter.
I agree , that my personal data will be used in accordance with the privacy policy of TRIOPTICS.
You need to enable Javascript for the anti-spam check. ×
Applications .
ImageMaster ? HR
The ImageMaster ? HR MTF test station measures visual and infrared lenses. The following parameters can be measured:
MTF on-axis and off-axis
Effective Focal Length (EFL)
Distortion
More .
Field curvature .
Lateral and longitudinal chromatic aberrations .
Astigmatism .
Chief Ray Angle .
PSF (Point Spread Function) .
Veiling Glare .
Depth of focus .
Field of view .
Flange Focal Length (FFL) relative .
Relative illumination .
All MTF measurements can be performed with the ImageMaster ? HR in finite and infinite measurement position.
ImageMaster ? HR TempControl .
In addition to determination of the MTF, the key measurement parameter is the change in both the flange focal length and effective focal length when the temperature changes.
In addition to military and aerospace applications, cameras are also being used in the automotive industry as safety-critical systems whose properties must be tested and ensured across a broad temperature span.
In general, the image quality of lenses can be affected by temperature influences on the optical components and mounting materials. Crucial lens parameters such as effective focal length and flange focal length can be temperature-dependent and have an impact on the camera’s focusing function.
Due to the easy system conversion from VIS to NIR, the specific requirements from various areas, including the automotive industry, development of mobile phone lenses, and the military and aerospace sectors are covered.
Measurement parameters:
Effective Focal Length (EFL)
Flange Focal Length (FFL)
MTF vs Frequency
More .
MTF vs Field .
MTF vs Focus .
MTF vs Focus vs Field .
Field curvature .
Distortion .
Depth of focus .
Chief Ray Angle .
ImageMaster ? Universal / ImageMaster ? Universal 3D
With the MTF test station ImageMaster ? Universal lenses can be measured in all spectral ranges from UV to LWIR.
The ImageMaster ? Universal 3D enables MTF measurements in the visible spectral range (VIS).
The following parameters can be measured:
MTF on-axis and off-axis
Effective Focal Length (EFL)
Distortion
More .
Field curvature .
Lateral and longitudinal chromatic aberrations .
Astigmatism .
Chief Ray Angle .
PSF (Point Spread Function) .
Depth of focus .
Field of view .
Back focal length (absolute/relative) .
Relative and absolute transmission .
Relative illumination .
All MTF measurements can be performed with the ImageMaster ? Universal in finite, infinite and afocal measurement position.
The ImageMaster ? Universal 3D enables measurements in finite and infinite measurement position.
Software .
ImageMaster ? MTF Lab Software .
User-friendly software for research and development as well as laboratory work.
Description .
Features .
MTF Lab for ImageMaster ? HR TempControl .
Description .
The versatile functionality and high performance make the user-friendly ImageMaster ? MTF-Lab software package the preferred choice for R&D and laboratory work. High-performance functions help the user to optimize the measurement processes.
The software offers high flexibility for measurements in the NUV-, VIS- and NIR spectrum. Automatic measurement sequences ensure easy operation and the data can be output in CSV/MHT.
Several useful functions are integrated which help the user to scan and perceive the correct image position of the sample under test. Changing the measurement mode is easy and time-saving. All important measurements for the imaging properties are quickly accessible.
One main feature key feature when using the software with the ImageMaster ? Universal is the support of UV or IR detectors employing the scanning aperture method.
Features .
Easy to handle graphical user interface makes the most important functions only one mouse-click away .
Customizable arrangement of graph windows .
Measurements of MTF, EFL and a range of other parameters using special target patterns and dedicated software routines .
Functions for easy alignment of the sample under test .
Conventional MTF measurement using a single slit or a crosshair as a target .
Optionally automated selection and positioning of the suitable reticle (target) and filter for the current application .
Configuration files with optimized process parameters and password protected access for operator and supervisor .
Script tools for custom programming and analysis .
Intuitive user interface and time-saving lens test routines .
Logging of successive measurements .
Data export to a variety of file formats .
The certificate in HTML format can be imported into MS Excel .
MTF Lab for ImageMaster ? HR TempControl .
For measurements in the temperature range from -40°C to 120°C, the proven MTF Lab software has been extended.
Powerful functions assist the user in performing the necessary measurement processes to determine a variety of parameters to determine the optical performance in the extended temperature range.
Measurements of MTF, EFL and a range of other parameters using special target patterns and dedicated software routines .
Functions for easy alignment of the sample under test .
Conventional MTF measurement using a single slit or a crosshair as a target .
Optionally automated selection and positioning of the suitable reticle (target) and filter for the current application .
Configuration files with optimized process parameters and password protected access for operator and supervisor .
Script tools for custom programming and analysis .
Intuitive user interface and time-saving lens test routines .
The certificate in HTML format can be imported into MS Excel .
Technical Data .
Parameter ImageMaster ? HR VIS ImageMaster ? HR IR ImageMaster ? HR MAX ImageMaster ? ? HR MAX IR ImageMaster ? HR UltraPrecision
Optical set up .
Infinite conjugates (finite optional) .
Infinite conjugates .
Infinite conjugates (finite optional) .
Infinite conjugates .
Max. off-axis angle .
Up to ±110° .
Up to ±110° .
Up to ±70° .
Up to ±70° .
Spectral range .
450 nm … 750 nm, halogen (NIR/NUV optional) .
LWIR: 8 ?m … 12 ?m .
VIS /NIR NUV optional .
NIR, NUV, LWIR: 8 ?m … 12 ?m VIS: 0.4 ?m … 0.9 ?m MWIR : 3 ?m … 5 ?m SWIR: 0.9 ?m … 1.7 ?m on request .
Azimuth range .
360° .
360° .
360° .
360° .
360° .
Max. image height .
±23 mm .
±23 mm .
±23 mm .
±23 mm .
±23 mm .
Clear aperture .
up to 100 mm .
up to 100 mm .
up to 100 mm .
Collimator range .
50 mm … 500 mm .
50 mm2) .
50 mm … 1,000 mm .
50 mm … 1,000mm2) .
50 mm … 1,000 mm .
EFL range of the sample .
1 mm … 150 mm 1) .
1 mm ... 10 mm 1),2) .
1 mm … 200 mm 1) .
1 mm … 200 mm 1) .
1 mm … 200 mm 1) .
Spatial frequency (in specification) Max. spatial frequency .
0 lp/mm … 500 lp/mm 1,000 lp/mm (depending on sample) .
0 lp/mm … 60 lp/mm .
0 lp/mm … 500 lp/mm 1,000 lp/mm (depending on sample) .
VIS/NIR/LWIR: 0 lp/mm … 60 lp/mm MWIR: 0 lp/mm … 100 lp/mm .
0 lp/mm … 500 lp/mm 1,000 lp/mm (depending on sample) .
Accuracy (MTF on-axis and off-axis) .
±0.02 MTF .
±0.03 MTF .
±0.02 MTF .
±0.03 MTF .
±0.02 MTF .
Repeatability (MTF on-axis and off-axis) .
±0.005 MTF .
±0.02 MTF .
±0.005 MTF .
±0.02 MTF .
±0.005 MTF .
1) Depends on mirror collimator 2) Larger on request
Download Technical Data ImageMaster? HR
Request ImageMaster? HR / HR TempControl / Universal
Upgrades & Accessories .
ImageMaster ? HR .
The ImageMaster ? HR is adapted to customer-specific measurement requirements by means of versatile upgrades.
For VIS and IR range .
For VIS range .
For Lenses and camera modules .
For VIS and IR range .
Motorized ultraprecise sample holder with a radial runout better than 3 μm / 6 arcsec for more accurate measurements of tilt sensitive samples .
Additional filters and reticles for all measurement applications: Filters for NUV, VIS, NIR / reticles extendable, e.g. for PSF and veiling glare measurements .
Extensions of nearly all stages to suit the customer’s needs .
For VIS range .
? Motorized finite conjugate stage with manual or motorized object generator. The motorized object generator illuminates the reticle in the direction of the sample for off-axis measurements. This is needed for small samples or low light conditions ? Various collimators with focal length and clear aperture for high flexibility ? Motorized reticle and filter changer for infinite conjugate to measure with least interaction of an operator. The lateral chromatic aberration can be measured more accurately as the filter will be changed automatically with no vibration of a manual change ? With the veiling glare upgrade for ImageMaster? HR it is possible to measure the Glare Spread Function (GSF). By off-axis measurements and rotation of the specimen around its center, the GSF can be measured over the entire field of view of the sample.
For Lenses and camera modules .
Upgrade ImageMaster ? HR to CamTest R&D
TRIOPTICS provides customers maximum versatility offering a combined test system. The three exchangeable measurement heads offer the following possibilities:
ImageMaster ? HR Image quality measurement of lenses with following parameter:
MTF on-axis and off-axis .
Effective Focal Length (EFL) .
Distortion .
Field curvature .
Lateral and longitudinal chromatic aberrations .
Astigmatism .
Chief Ray Angle .
PSF (Point Spread Function) .
Veiling Glare .
Depth of focus .
Field of view .
Flange Focal Length (FFL) relative .
Relative illumination .
CamTest R&D Image quality measurement of camera modules with following parameter:
Line Spread Function (LSF) .
MTF .
Distortion .
Effective Focal Length (EFL) .
Shift, tilt and defocus of the sensor .
Image field curvature of the lens .
Lateral and longitudinal chromatic aberrations .
ImageMaster ? HR TempControl .
A number of upgrades are available to extend the functionality of the ImageMaster ? HR TempControl:
Upgrade for measurements in the near infrared range .
Upgrade for LWIR- and MWIR-measurement .
Upgrade for distortion measurement .
Upgrade for ultra-precise FFL measurements .
Upgrade for measurements in the extended temperature range from -40°C to +120°C .
ImageMaster ? Universal .
Enhance the functionality of your ImageMaster ? Universal system with comprehensive upgrades and accessories.
Light Sources .
Detectors .
Sample Holder .
Finite Stage .
Reticles and Filters .
Afocal unit .
Light Sources .
Light sources for different wavelengths are available for the ImageMaster? Universal:
UV .
VIS / NIR / SWIR .
MWIR/LWIR .
MWIR/LWIR Light Source for ImageMaster ? Universal
Detectors .
Various camera based or scanning based detectors are available as image analyser for different wavelength ranges:
UV (scanning based) .
VIS (camera/scanning based) .
NIR (camera/scanning based) .
SWIR (scanning based) .
MWIR (kamera-/scannerbasiert) .
LWIR (kamera-/scannerbasiert) .
Camera VIS for ImageMaster ? Universal
Detector MWIR for ImageMaster ? Universal
Sample Holder .
Sample Holders for various diameters and a lifting table for large samples are available for the Image Master ? Universal.
Sample Holder for ImageMaster ? Universal
Lifting table for ImageMaster ? Universal
Finite Stage .
For finite conjugate measurements a finite stage is available as upgrade in two different stage lengths for all wavelength ranges:
Finite Stage 2m .
Finite Stage 3m .
Finite Stage for ImageMaster ? Universal
Reticles and Filters .
For different measurement requirements various reticles and filters are available. With the motorized reticle and filter changer they are changed easily and within short time. Reticle and filter changer .
Reticles .
Filter .
Reticle and Filter Changer
Reticles
Filters
Afocal unit .
The automated ultra-precision afocal unit is available as upgrade for afocal samples. With different autocollimator lenses for the afocal unit measurement in different wavelength ranges can be executed.
Afocal unit with
Decollimator lens for VIS .
Decollimator lens for MWIR .
Decollimator lens for LWIR .
Afocal unit
Knowledge Base .
MTF and image quality .
MTF Testing / Measurement / Inspection – Modulation Transfer Function .
The Modulation Transfer Function (MTF) is an important aid to objective evaluation of the image-forming capability of optical systems. Not only that the MTF provides a means of expressing the imaging quality of optical systems objectively and quantitatively, but it can be calculated from the lens design data. In this way it allows optical and systems designers to predict reliably the performance of the optical systems. The manufacturers can compare the image quality of the manufactured lenses with the design expectations.
The MTF measurement?is an important tool for the objective assessment of the imaging performance of optical systems. Moreover, the MTF can be calculated from the lens design data giving designers of optical systems the ability to predict system performance reliably. The manufacturer can then compare the image quality of real lenses with the expectations from the design phase.
MTF-Modulation Transfer Function .
The Modulation Transfer Function (MTF), describing the resolution and performance of an optical system, is the ratio of relative image contrast divided by relative object contrast MTF = Relative Image Contrast/Relative Object Contrast. When an object (illuminated target or reticle) is observed with an optical system, the resulting image will be somewhat degraded due to inevitable aberrations and diffraction phenomena. In addition, a real lens will not fully conform to the design data.
More knowledge for experts .
This article inspired you? Are you looking for further knowledge transfer? Then you might also be interested in the following topics…
WaveMaster ? (with Shack-Hartmann-Sensoren)
OptiSpheric ?
Perfect grid pattern is imaged through the sample into the image plane
Contrast vs spatial frequency. This figure shows the MTF of the diffraction limited optics and a measured MTF referring to Fig. 1
The image of a perfect slit is called “Line Spread Function”
Manufacturing errors, assembly and alignment errors in the optics will deteriorate the overall imaging performance of the system. As a result, in the image, bright highlights will not appear as bright as they do in the object, and dark or shadowed areas will not be as black as those observed in the original patterns. In general an illuminated target can be defined by its spatial frequency (number of bright and dark areas per millimeter) and the contrast (the apparent difference in brightness between bright and dark areas of the image).
By convention, the modulation transfer function is normalized to unity at zero spatial frequency. For low spatial frequencies, the modulation transfer function is close to 1 (or 100%) and generally falls as the spatial frequency increases until it reaches zero. The contrast values are lower for higher spatial frequencies as shown above. As spatial frequency increases, the MTF curve falls until it reaches zero. This is limit of resolution for a given optical system or the so called cut off frequency (see figure below). When the contrast value reaches zero, the image becomes a uniform shade of grey.
Typical setup for on-axis MTF measurements
The grids shown are actually no longer used in order to measure the MTF. Modern MTF-Testers like the ImageMaster ? ?use a single illuminated slit on opaque background as the object. From a mathematical point of view a single slit can be regarded as the sum over all spatial frequencies (Fourier synthesis). All frequencies contribute with the same amplitude (=1) to this slit not taking the finite slit width into account for this description. This single slit will be imaged into the image plane of the sample. Due to diffraction and aberrations there will be no perfect slit image in this plane, instead the slit image is broadened. It represents the so called Line Spread Function (LSF). On the basis of Fourier analysis the contribution of each spatial frequency to the LSF can be calculated. Actually the amplitude of each spatial frequency is equal to the contrast at this frequency. The Fourier analysis of the Lines Spread Function corresponds to the MTF of the sample. Taking a single image of the LSF unveils the complete MTF. Alternatively it is also possible to use a cross (i.e. two perpendicular slits) for the target. This enables the ImageMaster ? ?to measure the MTF in two image directions simultaneously provided a CCD camera is used for the image analyzer. And finally a pinhole target can be used as the object, too. The image of a pinhole target is called Point Spread Function. This function contains the complete MTF information in all image directions. The basic terms and mathematical relations used for MTF are described in the ISO 9334 standard.
The modulation transfer function varies not only related to the spatial frequency but also with the position in the field of view. The MTF measurement along the axis of symmetry of the optical system is known as on-axis measurement.
To completely characterize the imaging performance of an optical system, the MTF must be measured at different positions within the field of view. The MTF measurement within the field of view is known as off-axis measurement. In order to achieve an off-axis measurement, the target is moved in the field of view at the desired object position and the image analyzer to the corresponding image position.
The MTF measurement can be accomplished at a single wavelength or in a spectral range covering a finite band of wavelengths. The resulting measurement data are known as monochromatic or polychromatic MTF values, respectively.
Usually the MTF is used in its one-dimensional form, calculated for one azimuthal section through the image plane. The azimuth (section plane) of the object pattern is called sagittal azimuth when the prolongation of the slit or object passes through the reference axis. When the prolongation of the slit pattern is perpendicular to the reference axis, the azimuth is called tangential azimuth.
In this so-called finite-finite imaging condition the illuminated slit or crosshair target is directly moved in the object plane of the sample. In the more common infinite-finite imaging condition, the illuminated slit or crosshair is part of a collimator projecting the target to infinity. The collimator is then oriented at different off axis angles for characterizing the MTF at the corresponding image fields. Figure 4 shows the typical setup for this imaging condition.
Typical setup for off-axis MTF measurements
EFL .
The Effective Focal Length (EFL) or equivalent focal length is the distance from the focal points of the lens to the respective principal planes. The EFL determines the magnification of a lens and hence the image size. Because the principal planes are usually inside the lens at unknown locations, the direct measurement of the EFL is difficult.
However, the EFL can be measured quickly and with sufficient accuracy using the method of measuring the magnification of a double bar target. Certified master lenses from PTB (National German Standard Institute) are available at TRIOPTICS and are used for the calibration of the measurement setup. The measurement data are thus directly traceable to international standards.
EFL and Distortion .
Distortion is the percentage of change in magnification between the center of the field of view and off-axis?positions?in?the field of view. In order to determine the distortion a different method of measuring the EFL is used:
A MTF measurement on axis (at a selected frequency) is carried out. The paraxial focal plane is determined using the MTF measurement at a frequency of interest. To achieve a high accuracy monochromatic light and MTF curve fitting are used while the aperture of the lens is reduced by a diaphragm. .
An angular field range and a number of measurement points are selected. The object generator will automatically move to the selected field positions. .
At each position in field the image height is measured. A table with value pairs image height vs. field angles is provided. .
The EFL is calculated with the formula .
h/(tan α ) and drawn into a curve vs field angle. A polynomial fitting of the EFL close to α =0 allows the accurate and independent calculation of the paraxial focal length. .
The distortion is calculated as the ratio between paraxial and field focal length following the ISO 9039:2008. .
This procedure requires a comparatively large number of measurement points with accurately known object angles and field positions. For this reason ImageMaster ? instruments with dedicated distortion measurement option feature a high precision angular encoder for the object generator (accuracy 5 arcsec) and a high precision linear encoder for the image field stage (accuracy 0.2 μm). This way, the EFL is calculated as an absolute quantity, not depending on calibration parameters.
Depth of focus .
The depth of focus is the extent of the region in front of and behind the image plane in which the image will appear to be sharp.
The depth of focus can be determined using a “through focus scan” of the MTF and setting appropriate tolerances for the drop in MTF. The depth of focus between the set tolerances will be measured and displayed.
A more complex measurement can be done simulating the range of object distances covered by the lens and measuring the MTF at the corresponding image distances.
Field Curvature .
Field curvature is an optical aberration in which the focus position changes from the center to the edge of the field of view. The curvature of the image field is a lens aberration that causes a flat object surface to be imaged onto a curved surface rather than a plane.
In the presence of the astigmatism, there are two separate astigmatic focal surfaces in orthogonal directions.
To determine the field curvature a set of through focus measurements at different positions in the field are taken. The MTF maxima and the corresponding positions in field are determined. The values are collected by a software routine and displayed in graphical and tabular form.
?
Relative Illumination .
Relative illumination in an optical system is the gradual reduction of the image brightness with increased off-axis angle. This phenomenon results from the fall of, which is approximated by the cos4 or “cosine four law of the illumination falloff. Additionally there is the effect of the apparent limitation of the clear aperture depending on the field angle. Relative illumination is defined as the ratio of the central transmission and the transmission at the edge of the field of view.
The ImageMaster ? -Software measures continuously the light intensity of the test pattern in order to avoid saturation. In this way the necessary data is available for determining the relative illumination following ISO 13653:1996.
Chief Ray Angle (CRA) .
A chief ray is the ray from an off-axis object point which passes through the center of the aperture stop of an optical system. The chief ray enters the optical system along a line directed towards the midpoint of the entrance pupil, and leaves the system along a line passing through the center of the exit pupil. To measure the angle between the optical axis and the chief ray on the image side the following method is used: The lens under test is illuminated by the collimator at different angles corresponding to the object sided chief ray angles. The detector head is moved to the image field position at which the lens focuses the image. Now the detector head is moved towards the lens in small steps while the software registers the lateral movement of the focused spot. From these lateral movements the CRA is calculated.
Measurement procedure of chief ray angle
F-number .
The F-Number of a lens is defined by the ratio between the EFL and the diameter of the entrance pupil. The ImageMaster ? series instruments use the ISO-517 method to accomplish the measurement: First the EFL is measured according to the procedure described before. Then the sample is turned around with the entrance pupil facing towards the detector head. The diameter of the entrance pupil is measured by first focusing on the left, then on the right edge of the pupil. The travelling distance of the image field stage represents the diameter of the entrance pupil. By choosing the proper head lens of the detector head even pupils positioned far inside of the system under test can be measured.
Measurement procedure of F-number
Chromatic Aberrations .
Due to the dispersion of refractive optical systems the image position and also magnification of an optical system depends on the wavelength of the light. The dependence of the axial image position on the wavelength is called Chromatic Focal Shift. The dependence of the magnification on the wavelength is called Lateral Chromatic Aberration. Both aberrations can be measured with the ImageMaster ? . The collimator of the ImageMaster ? is equipped with different narrow bandwidth color filters. Together with the highly corrected relay optics this enables the system to focus in axial direction to the different image positions for different colors. The image position measurement can be done with submicron accuracy. Measuring the lateral image position for different object angles enables the system to measure the lateral chromatic aberration.
Principle of the measurement of the axial chromatic aberrations
Our Newsletter – Your advantage in knowledge .
Be one of the first to experience our product novelties and innovative application possibilities.
Register for the newsletter
× Sign up for the newsletter here: .
Be one of the first to experience our Product novelties and innovative application possibilities. .
Close .
From:
系统抽取对象
机构     
(1)